Aumeascon AM-MFM Electromagnetic Flow Meter

AM-MFM Electromagnetic Flow Meter

Aumeascon Electromagnetic flow meters , also known as Magnetic flow meters or mag meters, are often selected because they are obstruction less, cost-effective, bi-directional, and provide highly accurate volumetric flow measurement. A range of liner materials, electrode options and line sizes accommodate a wide variety of process applications. For aggressive high noise applications, look to our Slurry Platform for optimum performance.  See if a Slurry mag meter meets your needs.

 

Working principle

Electromagnetic flow meters, or magmeters, are comprised of a transmitter and sensor that together measure flow. The magnetic flow meters sensor is placed inline and measures an induced voltage generated by the fluid as it flows through a pipe. The transmitter takes the voltage generated by the sensor, converts the voltage into a flow measurement and transmits that flow measurement to a control system.

 

Technical Parameters

Model

AM-MFM Electromagnetic Flow Meter

Structure

Inserted style, integreated type or separated type

Medium

Liquid or solid-liquid two phase fluid, conductivity >5us/cm2

DN (mm)

6mm-2600 mm

Output

4-20mA ,pulse or frequency

Communication

 RS485, Hart (optional)

Connection

 Thread,flange,tri-clamp

Power

AC86-220V, DC24V ,battery

Lining

Lining:rubber,polyurethane rubber,chloroprene rubber,PTFE,FEP

electrode

Electrode:SS316L,hastelloy B,hastelloy C,platinum,Tungsten carbide

 

Selection of Electrode

Electrode

Suitable medium liquid

SS316L

domestic water, industrial water, raw water well water, urban sewage, weak corrosive acid, alkali,

Hastelloy B

non-oxidizing acid such as hydrochloric acid with concentration less than 10%, sodium hydroxide with concentration less than 50%, alkali hydroxide solution at all concentrations; phosphoric acid and organic acid;

Not for:  nitric acid

Hastelloy C

mixed acid (such as mixed solution of chromic acid and sulfuric acid); oxidizing salts (such as seawater, containing Cu+++, Fe+++)

Not for: hydrochloric acid

Titanium Alloy

salt (such as chloride, sodium salt, potassium salt, ammonia salt, hypochlorite, sea water), potassium hydroxide, ammonium hydroxide, cerium hydroxide solution with concentration less than 50%;  reducing acids such as hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid;

Tantalum

hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid); chlorine dioxide, ferric chloride, hypochlorous acid, sodium chloride, lead acetate, etc.; nitric acid (including fuming nitric acid) Aqueous acid), aqua regia with a temperature below 80 ° C;

Not for:  alkali, hydrofluoric acid

Platinum

Almost all acid-base solutions (including fuming sulfuric acid and fuming nitric acid)

Not for: aqua regia, ammonia salt

Tungsten carbide

Suitable for:  pulp, sewage, mud, resistant to solid particles

Not for:  inorganic acids, organic acids and chlorides

Selection of Lining

Lining

Performance

Max Temp

Liquids

Neoprene

(CR)

Medium abrasion resistance, general acid salt solution

80℃

Tap water, industrial water, sea water

Polyurethane

Rubber (PU)

Excellent wear resistance and poor acid and alkali resistance

80℃

Slurry, pulp, mud, etc.

PTFE

Stable chemical properties, corrosion resistance to boiling hydrochloric acid, sulfuric acid, aqua regia, concentrated alkali

140℃

Corrosive acid-base salt solution

Polyperfluoroethylene propylene

(F46)

Chemical properties equivalent to PTFE, tensile strength, tensile strength better than PTFE

180℃

Corrosive acid-base salt solution

 

Recommended material for different application

Application

Medium

Electrode

Lining

Housing

Chemical fiber

Acid dosing

HC/Tantalum

PTFE

Carbon steel

Alkali dosing

Titanium

PTFE

Carbon steel

Food

Add water in proportion

316L

PTFE

Carbon steel

corn steep liquor, beer, fiber pulp, beverage

316L

F46(high temperature cleaning)

304/316

(Sanitary)

Environmental protection

Electroplating wastewater

 (acidic cu2+, Fe2+)

Tantalum

PTFE

Carbon steel

Electroplating wastewater

 (alkali, NaOH, etc.)

Titanium

PTFE

Carbon steel

Electroplating wastewater

 (both acid and alkali)

Platinum

PTFE

Carbon steel

Printing and dyeing wastewater (bleaching and adding acid)

Tantalum

PTFE

Carbon steel

Printing and dyeing wastewater (neutralization and alkali addition)

Titanium

PTFE

Carbon steel

Municipal pipe network, domestic sewage, tap water

SS316L

PTFE/

Rubber

Carbon steel

Sewage plant flocculant dosing (polyaluminum chloride)

Tantalum

PTFE

Carbon steel

Paper Making

Finished pulp (moisture content above 70%)

SS316L

PTFE

Carbon steel

Papermaking white liquor

Tantalum

PTFE

Carbon steel

Mining and metallurgy

Mud. Slurry

316L/Tungsten carbide

polyurethane

Carbon steel

 Contact info:

Shanghai Aumeascon Automation Technology Company 

Website:www.aumeascon.com 

Mob/WA:86-18721238342 

Email: Sales@aumeascon.com, aumeascon@gmai.com

Address:No. 95, Shihu New Road, Shihudang Town, Songjiang District, Shanghai.China , Zip code:201604